Renewable energy resources are being used to overcome energy shortage. From the point of view of energy management the interconnectivity of electric utility with renewable energy resources is difficult. Renewable energy resources need to be managed with electric utility. A Smart Energy Management System (SEMS) is designed and developed for monitoring an efficient load management of electric utility and photovoltaic power system is presented in this research. The design consists of an Energy Management Center (EMC) and Field Programmable Gate Array (FPGA). Energy Management Center shows the runtime data and also keeps the data log and offers control of the load shifting between utility source and photovoltaic power system. Analog to digital converter is used to interface the current and voltage sensors with FPGA. ZigBee is connected for wireless radio data transmission between the FPGA and energy management & monitoring center. The SEMS increases the efficiency of energy up to 10.5 percent in comparison with normal systems.
Published in | American Journal of Electrical Power and Energy Systems (Volume 3, Issue 5) |
DOI | 10.11648/j.epes.20140305.11 |
Page(s) | 86-94 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2014. Published by Science Publishing Group |
FPGA, Energy Management, ZigBee, Renewable Energy, Smart Grid
[1] | Insung Hong, Byeongkwan Kang, and Sehyun Park “Design and Implementation of Intelligent Energy Distribution Management with Photovoltaic System” IEEE Transactions on Consumer Electronics, Vol. 58, No. 2, May 2012 |
[2] | Saifur Rahman, Manisa Pipattanasomporn and Murat Kuzlu “An Algorithm for Intelligent Home Energy Management and Demand Response Analysis” IEEE Transactions on SMART GRID, Vol. 3, 2012, Page(s): 2166 – 2173 |
[3] | Shaalan , Hesham E. “ Generation of Electric Power” Hand book of Electric power calculation,3rd ed. 2003, Mc-Graw-Hill. |
[4] | Kaplan, S. M. Smart Grid Electrical Power Transmission: Background and Policy Issues. The Capital.Net, Government Series. 2009 Page(s): 1-42 |
[5] | F.Baig, A.Mahmood, N.Javaid, S.Razzaq, N.Khan and Z.Saleem “Smart Home Energy Management System for Monitoring and Scheduling of Home Appliances Using Zigbee” Journal of Basic and Applied Scientific Research, 2013, Page(s)880-891. |
[6] | Xunming Dengand, Eric A. Schiff “Amorphous Silicon–based Solar Cells” University of Toledo, Toledo, OH, USA, Syracuse University, Syracuse, NY, USA |
[7] | K. Touafek, M. Haddadi, and A. Malek, "Modeling and Experimental Validation of a New Hybrid Photovoltaic Thermal Collector," Energy Conversion, IEEE Transactions on, vol. 26, pp. 176-183, 2011. |
[8] | Xiaobin Huang, Beibei Jiang “Research on Lithium Battery Energy Storage System” IEEE Journals & Magazines, 2011 |
[9] | Anjali Singhal and R.P. Saxena “Software Models for Smart Grid” IEEE, SE-Smart Grids, Zurich, Switzerland, 2012, Page(s): 42 – 45 |
[10] | Frank Vahid “Digital Design with RTL Design, Verilog and VHDL” 2010. John Wiley and Sons. p. 247. ISBN 978-0-470-53108-2. |
[11] | Pradeep.P*, T.D.Sunil and M.Z.Kurian “Design of power management system using artificial intelligence based on FPGA” World Journal of Science and Technology 2012, 2(10):56-60 |
[12] | Xiaobin Huang, Beibei Jiang “Research on Lithium Battery Energy Storage System” IEEE Journals & Magazines, 2011 |
[13] | Zhang Guoju , Tang Xisheng, Qi zhiping “Research on Battery Supercapacitor Hybrid Storage and its application in MicroGrid” IEEE Journals & Magazines,2010. |
[14] | Kyle Thomas, V. A. Centeno, A. G. Phadke “Three-phase Instrument Transformer Calibration with Synchronized Phasor Measurements” IEEE Journals & Magazines, 2011. |
[15] | James Momoh, SMART GRID Fundamentals of Design and Analysis, IEEE Press Series John Wiley & Sons, 2012 |
[16] | A Hajizadeh and MA Golkar. “Intelligent power management strategy of hybrid distributed generation system”. International journal of Electrical Power and Energy System, 29(10), 2007. |
[17] | G Dawei, J Zhenhua, and L Qingchun. “Energy management strategy based on fuzzy logic for a fuel cell hybrid bus”. Journal of Power Sources, 1(185), 2008. |
[18] | Abbas A. Akhil, Georgianne Huff, Aileen B. Currier, Benjamin C. Kaun, Dan M. Rastler, Stella Bingqing Chen, Andrew L. Cotter, Dale T. Bradshaw, and William D. Gauntlett, “DOE/EPRI 2013 Electricity Storage Handbook in Collaboration with NRECA” Sandia National Laboratories Albuquerque, New Mexico and Livermore, California, July 2013 |
[19] | S Abras, S Ploix, S Pesty, and M Jacomino.” A multi- agent design for a home automation system dedicated to power management”. In Christos Boukis, Aristodemos Pnevmatikakis, and Lazaros Polymenakos, editors, AIAI, volume 247 of IFIP, pages 233–241, 2007. |
[20] | Clark W. Gellings, P.E. “The Smart Grid: Enabling Energy Efficiency and Demand Response” e Fairmont Press, Inc., 2009. |
APA Style
Yousaf H. Khattak, Tahir Mahmood, Khurshid Alam, Tahir Sarwar, Inayat Ullah, et al. (2014). Smart Energy Management System for Utility Source and Photovoltaic Power System Using FPGA and ZigBee. American Journal of Electrical Power and Energy Systems, 3(5), 86-94. https://doi.org/10.11648/j.epes.20140305.11
ACS Style
Yousaf H. Khattak; Tahir Mahmood; Khurshid Alam; Tahir Sarwar; Inayat Ullah, et al. Smart Energy Management System for Utility Source and Photovoltaic Power System Using FPGA and ZigBee. Am. J. Electr. Power Energy Syst. 2014, 3(5), 86-94. doi: 10.11648/j.epes.20140305.11
AMA Style
Yousaf H. Khattak, Tahir Mahmood, Khurshid Alam, Tahir Sarwar, Inayat Ullah, et al. Smart Energy Management System for Utility Source and Photovoltaic Power System Using FPGA and ZigBee. Am J Electr Power Energy Syst. 2014;3(5):86-94. doi: 10.11648/j.epes.20140305.11
@article{10.11648/j.epes.20140305.11, author = {Yousaf H. Khattak and Tahir Mahmood and Khurshid Alam and Tahir Sarwar and Inayat Ullah and Hanif Ullah}, title = {Smart Energy Management System for Utility Source and Photovoltaic Power System Using FPGA and ZigBee}, journal = {American Journal of Electrical Power and Energy Systems}, volume = {3}, number = {5}, pages = {86-94}, doi = {10.11648/j.epes.20140305.11}, url = {https://doi.org/10.11648/j.epes.20140305.11}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.epes.20140305.11}, abstract = {Renewable energy resources are being used to overcome energy shortage. From the point of view of energy management the interconnectivity of electric utility with renewable energy resources is difficult. Renewable energy resources need to be managed with electric utility. A Smart Energy Management System (SEMS) is designed and developed for monitoring an efficient load management of electric utility and photovoltaic power system is presented in this research. The design consists of an Energy Management Center (EMC) and Field Programmable Gate Array (FPGA). Energy Management Center shows the runtime data and also keeps the data log and offers control of the load shifting between utility source and photovoltaic power system. Analog to digital converter is used to interface the current and voltage sensors with FPGA. ZigBee is connected for wireless radio data transmission between the FPGA and energy management & monitoring center. The SEMS increases the efficiency of energy up to 10.5 percent in comparison with normal systems.}, year = {2014} }
TY - JOUR T1 - Smart Energy Management System for Utility Source and Photovoltaic Power System Using FPGA and ZigBee AU - Yousaf H. Khattak AU - Tahir Mahmood AU - Khurshid Alam AU - Tahir Sarwar AU - Inayat Ullah AU - Hanif Ullah Y1 - 2014/10/20 PY - 2014 N1 - https://doi.org/10.11648/j.epes.20140305.11 DO - 10.11648/j.epes.20140305.11 T2 - American Journal of Electrical Power and Energy Systems JF - American Journal of Electrical Power and Energy Systems JO - American Journal of Electrical Power and Energy Systems SP - 86 EP - 94 PB - Science Publishing Group SN - 2326-9200 UR - https://doi.org/10.11648/j.epes.20140305.11 AB - Renewable energy resources are being used to overcome energy shortage. From the point of view of energy management the interconnectivity of electric utility with renewable energy resources is difficult. Renewable energy resources need to be managed with electric utility. A Smart Energy Management System (SEMS) is designed and developed for monitoring an efficient load management of electric utility and photovoltaic power system is presented in this research. The design consists of an Energy Management Center (EMC) and Field Programmable Gate Array (FPGA). Energy Management Center shows the runtime data and also keeps the data log and offers control of the load shifting between utility source and photovoltaic power system. Analog to digital converter is used to interface the current and voltage sensors with FPGA. ZigBee is connected for wireless radio data transmission between the FPGA and energy management & monitoring center. The SEMS increases the efficiency of energy up to 10.5 percent in comparison with normal systems. VL - 3 IS - 5 ER -